dc.description.abstractAs discussed in this chapter, the commercialization and adoption bottlenecks for these moderately complex diagnostics cannot be overcome by technological innovation alone, particularly in the highly regulated and payer-limited healthcare and public health markets. Diagnostics, unlike other clinical products, is not an intervention but a decision-aid that guides the use (or nonuse) of an intervention. It is important that the value proposition for any technology-centric innovation in diagnostics include a strong link to a gained efficiency in making a specific decision. Any assay developed without context to the system, users, decision points, and downstream interventions resembles one that is more targeted to the research community, rather than clinical care or public health.
dc.languageEnglish
dc.rightsopen access
dc.subject.otheruser needs
dc.subject.otherdeveloping diagnostics
dc.subject.otheruser needs
dc.subject.otherdeveloping diagnostics
dc.subject.otherDecision problem
dc.subject.otherDecision-making
dc.subject.otherGlobal health
dc.subject.otherHealth care
dc.subject.otherInfrastructure
dc.subject.otherProduct requirements document
dc.subject.otherPublic health
dc.subject.otherUse case
dc.subject.otherWorkflow
dc.subject.otherWorld Health Organization
dc.subject.otherthema EDItEUR::M Medicine and Nursing
dc.titleChapter 9 Starting with the End in Mind by Developing Diagnostics around User Needs
dc.typechapter
oapen.relation.isPublishedByfa69b019-f4ee-4979-8d42-c6b6c476b5f0
oapen.relation.isPartOfBookDiagnostic Devices with Microfluidics
oapen.relation.isPartOfBook9d2d7409-f177-4974-8947-d9109eab6f09
oapen.relation.isPartOfBook037ae638-4d4a-40d0-bc3b-5b63103fd855
oapen.imprintCRC Press
oapen.pages14
dc.chapternumber1


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

open access
Except where otherwise noted, this item's license is described as open access